1、電源安裝接線不規范新購置的電表箱、低壓無功補償裝置柜,由于生產廠家的不同,在安裝電源線的接線方法上也不相同,主要與廠家在低壓無功補償裝置柜上配置的無功功率自動補償控制器JKG系列(簡稱:控制器)的取樣檢測信號電源有關,有的儀器的取樣電流和取樣電壓要同相,有的是不要求同相。鄂爾多斯低壓配電柜2、取樣檢測信號倍率選擇不當取樣用的電流互感器,有的選擇的CT倍率過大,使得控制器的取樣的二次電流過小處于"欠流"指示狀態,有的選擇的CT倍率過小,使得控制器的取樣的二次電流過大,控制器的取樣檢測信號電流一般不超過5A,否則就會燒壞控制器的塑料接線端子和內部原件。低壓配電柜廠家3、電(dian)(dian)(dian)容(rong)器(qi)(qi)(qi)的(de)(de)(de)額(e)定電(dian)(dian)(dian)壓偏低2000年之前(qian)生(sheng)產的(de)(de)(de)低電(dian)(dian)(dian)壓并聯(lian)電(dian)(dian)(dian)容(rong)器(qi)(qi)(qi)的(de)(de)(de)額(e)定電(dian)(dian)(dian)壓大多數是400V,而隨(sui)著(zhu)農網(wang)改造和電(dian)(dian)(dian)能質量的(de)(de)(de)不斷提高,目前(qian),電(dian)(dian)(dian)網(wang)電(dian)(dian)(dian)壓特別(bie)是配電(dian)(dian)(dian)變壓器(qi)(qi)(qi)的(de)(de)(de)首端(duan),電(dian)(dian)(dian)源電(dian)(dian)(dian)壓一(yi)般都要超過400V,有的(de)(de)(de)達(da)420V左右。而低壓無功(gong)補(bu)償裝置柜(ju)都是安裝在(zai)配電(dian)(dian)(dian)變壓器(qi)(qi)(qi)低壓線(xian)母線(xian)側,處于電(dian)(dian)(dian)源的(de)(de)(de)最前(qian)端(duan),此時,電(dian)(dian)(dian)容(rong)器(qi)(qi)(qi)長期(qi)在(zai)高于其額(e)定電(dian)(dian)(dian)壓狀態(tai)下運行,縮短(duan)了壽命。

日常保養1、定期檢查各柜內是否有蟲鼠活動的痕跡,定期進行誘殺。2、檢查各警告牌、檢修牌擺放位置是否正確。鄂爾多斯低壓配電柜3、檢查應急工具、燈具是否齊全、正常,搖把及熔斷器手柄是否齊全。4、檢查電纜接頭有無發熱變色(一般都為銀色),接地線有無銹蝕(焊接點是否正常)5、檢查電容柜內的電容器外殼是否良好,有無滲漏、膨脹情況,指示燈是否良好。6、檢查各電容器外殼接地線接觸情況7、做好各柜休的保潔除塵工作。8低壓配電柜廠家、檢查各柜體的風扇工作情況。

我們首先來了解下什么是特高壓,以及它對于輸配電設備配電柜的要求是怎樣的?特高壓,縮寫UHV,在中國,特高壓是指交流1000千伏、直流±800千伏及以上的電壓等級。特高壓直流輸電具備點對點、超遠距離、大容量送電能力,鄂爾多斯低壓配電柜主要定位于我國西南大水電基地和西北大煤電基地的超遠距離、超大容量外送。據業內媒體報道,--總理的表態直接停息了業界關于特高壓要不要建設的爭論。特高壓不僅要建,低壓配電柜廠家而且要(yao)建設(she)一批,今年(nian)有(you)望成為特高壓(ya)(ya)審批與(yu)建設(she)的“大(da)年(nian)”。而想使用(yong)起(qi)來特高壓(ya)(ya)輸(shu)配(pei)電(dian)系統(tong),也不是那么容易的。需要(yao)注(zhu)(zhu)意的關(guan)鍵(jian)技術問(wen)題(ti)(ti)就有(you)很多:1、采用(yong)±800千伏(fu)特高壓(ya)(ya)直(zhi)流輸(shu)電(dian),要(yao)注(zhu)(zhu)重受端電(dian)網靜態無功(gong)(gong)功(gong)(gong)率(lv)平衡和動態無功(gong)(gong)功(gong)(gong)率(lv)備用(yong)及電(dian)壓(ya)(ya)穩定性問(wen)題(ti)(ti),2、要(yao)注(zhu)(zhu)重多回直(zhi)流饋入系統(tong)因同時換(huan)相失(shi)敗引起(qi)的系統(tong)電(dian)壓(ya)(ya)安(an)全問(wen)題(ti)(ti)。采用(yong)1000千伏(fu)交(jiao)(jiao)流輸(shu)電(dian),3、要(yao)注(zhu)(zhu)重運行方式(shi)變(bian)化時的交(jiao)(jiao)流系統(tong)調相調壓(ya)(ya)問(wen)題(ti)(ti);4、要(yao)注(zhu)(zhu)重嚴重故(gu)障(zhang)條件下(xia),相對薄弱(ruo)斷(duan)面大(da)功(gong)(gong)率(lv)轉移等問(wen)題(ti)(ti);5、要(yao)注(zhu)(zhu)重大(da)面積(ji)停電(dian)事(shi)故(gu)隱患及其預防(fang)措(cuo)施(shi)。 與(yu)超高壓(ya)(ya)直(zhi)流輸(shu)電(dian)相比,

1.實行分段保養,先保養保安負荷段.2.停保安負荷電,其余負荷照常供市電.斷開供保安負荷市電的空氣開關,斷開發電機空氣開關,把發電機選擇開關置于停止位置,拆開蓄電池正,負極線,掛標示牌,以防發電機發送電.生產低壓配電柜3.箱式變電站廠家認為要檢查母線接頭處有無變形,有無放電變黑痕跡,緊固聯接螺栓,螺栓若有生銹應予更換,確保接頭連接緊密.檢查母上的絕緣有無松動和損壞.4.箱式變電站廠家認為要用手柄把總空氣從配電柜中搖出,檢查主觸點是否有燒溶痕跡,檢查滅弧罩是否燒黑和損壞,緊固各接線螺絲、鄂爾多斯低壓配電柜清潔柜(ju)內(nei)灰塵(chen)(chen),試驗(yan)機(ji)(ji)械的(de)合閘,分(fen)閘情況5.把各(ge)分(fen)開(kai)關(guan)柜(ju)從(cong)抽屜(ti)柜(ju)中取出,緊固各(ge)接線端子.檢查電(dian)(dian)(dian)流互感器(qi),電(dian)(dian)(dian)流表(biao),電(dian)(dian)(dian)度表(biao)的(de)安裝和接線,檢查手柄操作(zuo)機(ji)(ji)構(gou)的(de)靈活(huo)可靠性,緊固空氣開(kai)關(guan)進(jin)出線,清潔開(kai)關(guan)柜(ju)內(nei)和配(pei)電(dian)(dian)(dian)柜(ju)后面引出線處的(de)灰塵(chen)(chen)6.箱(xiang)式變電(dian)(dian)(dian)站廠家認為負荷段(duan)保(bao)養完畢,可起動發(fa)電(dian)(dian)(dian)機(ji)(ji)對其供電(dian)(dian)(dian),停市電(dian)(dian)(dian)保(bao)養母線段(duan).逐(zhu)級(ji)斷開(kai)低壓(ya)側(ce)空氣開(kai)關(guan),然后斷開(kai)供變壓(ya)器(qi)電(dian)(dian)(dian)的(de)高(gao)壓(ya)側(ce)真空斷路器(qi),合上接地開(kai)關(guan).